Ê×Ò³ > ¼¼ÊõÎÄÕÂ
Ô×°µÂ¹úÒ׸£Ãűõ¹ó²Ñµç´ÅÁ÷Á¿¼Æ³§²Ñ6000ÐͲúÎïÌØÕ÷£º
ÊäÈëºÍÊä³ö×ÜÊýÊý×ÖÊä³öÊýÁ¿: 2; Ä£ÄâÊä³öÊýÁ¿: 1
²âÁ¿·¶Î§
0.1...25 l/min0.005...1.5 m?/h
ϵͳ½Ó¿ÚÂÝÎÆÁ¬½Ó G 1/2 DN15 ±âƽÃÜ·â
Ó¦ÓÃ
ÌØÊâµÄÐÔÄܶƽ𴥵ã
Ó¦Óüӷ¨Æ÷¹¦ÄÜ; ÓÃÓÚ¹¤ÒµÓ¦ÓÃ
°²×°Í¨¹ýÊÊÅäÆ÷Á¬½Ó¹ÜµÀ
½éÖʵ¼µçÒºÌå; Ë®; ˮΪ»ù±¾µÄ½éÖÊ
½éÖÊ˵Ã÷
µçµ¼ÂÊ: ≥ 20 ?S/cm
Õ³ÐÔ: < 70 mm?/s (40 °C)
½éÖÊÎÂ¶È [°C]-10...70
¿¹Ñ¹Ç¿¶È [bar]16
ÔÊÐí¹¤×÷ѹÁ¦µÄ´óÖµ£¨ÓÃÓÚÓ¦ÓóÌÐò·ûºÏCRN±ê×¼£© [bar]17.7
µçÆøÊý¾Ý
¹¤×÷µçѹ [V]18...30 DC; (·ûºÏEN 50178 SELV/PELV±ê×¼)
µçÁ÷ËðºÄ [mA]95; (24 V)
¾øÔµµç×èСֵ [MΩ]100; (500 V DC)
·À»¤µÈ¼¶±õ±õ±õ
·´Ïà±£»¤ÓÐ
¿ª»úÑÓ³Ùʱ¼ä [s]5
×ܵÄÊäÈë/Êä³ö
ÊäÈëºÍÊä³ö×ÜÊýÊý×ÖÊä³öÊýÁ¿: 2; Ä£ÄâÊä³öÊýÁ¿: 1
ÊäÈë
ÊäÈë¼ÆÊýÆ÷¸´Î»
Êä³ö
Êä³öÊýÁ¿2
Êä³öÐźſª¹ØÐźÅ; Ä£ÄâÐźÅ; Âö³åÐźÅ; IO-Link; (¿ÉÅäÖÃ)
µçÆøÉè¼Æ±Ê±·±Ê/±·±Ê±·
Êý×ÖÊä³öÊýÁ¿2
Êä³ö¹¦Äܳ£¿ª/³£±Õ; (¿ÉÉ趨²ÎÊý)
¿ª¹ØÁ¿Êä³öDCµçѹ½µ´óÖµ [V]2
¿ª¹ØÁ¿Êä³öDCµÄ³ÖÐøµçÁ÷¸ºÔØ [mA]200
Ä£ÄâÊä³öÊýÁ¿1
Ä£ÄâµçÁ÷Êä³ö [mA]4...20; (¿Éµ÷ÕûÁ¿³Ì)
¸ºÔØ´óÖµ [Ω]500
Ä£ÄâµçѹÊä³ö [V]0...10; (¿Éµ÷ÕûÁ¿³Ì)
¸ºÔصç×èСֵ [Ω]2000
Âö³åÊä³öÁ÷Á¿¼Æ
¶Ì·±£»¤ÓÐ
¶Ì·±£»¤ÀàÐÍÂö³å
¹ýÔر£»¤ÓÐ
²âÁ¿/É趨·¶Î§
²âÁ¿·¶Î§
0.1...25 l/min0.005...1.5 m?/h
ÏÔʾ·¶Î§
-30...30 l/min-1.8...1.8 m?/h
·Ö±æÂÊ
0.02 l/min0.002 m?/h
¿ª¹Øµã, SP
0.25...25 l/min0.015...1.5 m?/h
¸´Ôµã, rP
0.1...24.9 l/min0.005...1.495 m?/h
²âÁ¿ÖµÆðµã, ASP
0...20 l/min0...1.2 m?/h
²âÁ¿ÖµÖÕµã, AEP
5...25 l/min0.3...1.5 m?/h
²½¾à
0.02 l/min0.002 m?/h
Á÷Á¿¼à¿Ø
Âö³åÖµ0.00001...30 000 m?
Âö³å³¤¶È [s]0,01...2
ζȼà¿Ø
²âÁ¿·¶Î§ [°C]-20...80
·Ö±æÂÊ [°C]0.2
¿ª¹Øµã, SP [°C]-19.2...80
¸´Ôµã, rP [°C]-19.6...79.6
²âÁ¿ÖµÆðµã [°C]-20...60
²âÁ¿ÖµÖÕµã [°C]0...80
É趨²½¾à [°C]0.
·´Ó¦Ê±¼ä
Á÷Á¿¼à¿Ø
·´Ó¦Ê±¼ä [s]0.15; (dAP = 0, T19)
¿É±à³ÌµÄÑÓ³Ùʱ¼ädS, dr [s]0...50
ÓÃÓÚ¿ª¹ØÁ¿Êä³öµÄ×èÄádAP [s]0...5
ζȼà¿Ø
ÏìӦʱ¼äT05 / T09 [s]T09 = 20 (Q > 1 l/min)
Èí¼þ/±à³Ì
²ÎÊýÉ趨Á÷Á¿¼à¿Ø; ÊýÁ¿¼Æ; Ô¤ÉèÈÝÁ¿¼Æ; ζȼà¿Ø; ³ÙÖÍ/´°¿Ú; ³£¿ª/³£±Õ; Êä³ö¼«ÐÔ; µçÁ÷/µçѹ/Âö³åÊä³ö; Æô¶¯ÑÓ³Ù; ÏÔʾ¿ÉÒԹرÕ; ÏÔʾµ¥Î»
½Ó¿Ú
ͨÐŽӿڱõ°¿-³¢¾±²Ô°ì
´«µÝÀàÐÍCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI±ê×¼IEC 61131-9
IO-Link Device ID569 / 00 02 39 h
ÍâÐÎSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
³§±õ°¿Ä£Ê½ÓÐ
±ØÐèµÄmater port typeA
Ä£Äâ¹ý³ÌÊý¾Ý3
¶þλÊä³ö¹ý³ÌÊý¾Ý2
´¦ÀíÖÜÆÚСֵ [ms]5
¹¤×÷Ìõ¼þ
»·¾³ÎÂ¶È [°C]-10...60
´æ´¢ÎÂ¶È [°C]-25...80
Íâ¿Ç·À»¤µÈ¼¶IP 67
ÈÏÖ¤/²âÊÔ
·¡²Ñ°äµç´Å¼æÈÝ
DIN EN 60947-5-9
¿¹³å»÷
DIN IEC 68-2-2720 g (11 ms)
¿¹Õð
DIN IEC 68-2-65 g (10...2000 Hz)
MTTF [Äê]162
³ÐѹÉ豸ָÁîÁ¼ºÃµÄ¹¤³Ìʵ¼ù; ¿ÉÓÃÓÚµÚ2×éÁ÷Ìå; ¸ù¾ÝÐèÇóÁ÷Ìå×é1µÄÁ÷Ìå
»úе¼¼ÊõÊý¾Ý
ÖØÁ¿ [g]542.5
Ô²ÄÁϲ»Ðâ¸Ö(1.4404 / 316L); PBT-GF20; PC; FKM; TPE
²ÄÁÏ(³±Êª²¿¼þ)²»Ðâ¸Ö(1.4404 / 316L); PEEK; FKM
ϵͳ½Ó¿ÚÂÝÎÆÁ¬½Ó G 1/2 DN15 ±âƽÃÜ·â
ÏÔʾÆ÷/²Ù×÷¼þ
ÏÔʾ
ÏÔʾµ¥Î»6 x LED, ÂÌÉ« (l/min, m?/h, l, m?, 10?, °C)
¿ª¹Ø״̬2 x LED, »ÆÉ«
²âÁ¿Öµ×ÖĸÊý×ÖÏÔʾ, 4λÊý×Ö
±à³Ì×ÖĸÊý×ÖÏÔʾ, 4λÊý×Ö
×¢ÊÍ
×¢ÊÍ
MW = ²âÁ¿Öµ
MEW = Final value of the measuring range